Banner

news

Home>news>Content

Common faults and solutions of breakers

2021-03-17

1, the frequency drops

  HammerThere are many reasons for the reduction in frequency, such as insufficient pressure or flow in the hydraulic system, loose drill pipe, worn hydraulic seals, contamination of hydraulic oil, and failure of safety valves.

Solution: Check the oil pump of the equipment, adjust the oil pressure and flow rate that is too high or too low to control the hammer; check the oil circuit of the equipment to avoid blockage of the pipeline and affect the impact frequency of the equipment; replace the worn parts. Tighten the drill rod and fix the drill rod.

2, the strength is reduced

The decrease in strength is caused by oil leakage, insufficient stroke of the control bolts of the equipment, blockage of the oil circuit and excessively high oil temperature. These will cause the impact force of the equipment to be reduced, the impact stroke to be insufficient, and the overall working performance to decline.

Solution: Check and adjust hydraulic system and nitrogen pressure. If parts seal poorly, parts can be ground or replaced to clean hydraulic lines.

破碎锤

3, discontinuous action

3 main cases of poor continuity of action. First, the oil passage is blocked, which results in poor oil supply, and the piston cannot get stable power. Insufficient pressure in the hydraulic system, the diverter valve is in the wrong direction, the piston is stuck , failure of the shut-off valve, etc., resulting in problems such as electric shock stagnation. Then the sticking of the drill pipe occurs, which will affect the continuity and periodicity of the hydraulic breaker.

Solution: Check the hydraulic oil circuit, clean or replace the stuck parts in time; focus on checking the direction of the oil pipe interface, reversing valve, stop valve and piston; check and adjust the state of the drill pipe, and use the grinding wheel for the problematic drill pipe Or the whetstone has been polished, and lubricating oil should be added in time.

4, oil leakage

The main cause of oil leakage is excessive wear of seals and other parts, resulting in poor sealing performance. Loose oil connections.

Solution: According to the specific location of the oil leakage, replace the corresponding sealing ring and tighten the oil pipe joint.

5. Abnormal vibration of equipment tubing

The leakage diaphragm of the accumulator is damaged, and the nitrogen pressure of the hammer handle body is reduced.

Solution: Check the air pressure of the accumulator. If the specified pressure cannot be maintained, check the diaphragm for damage. In addition, the nitrogen pressure of the hydraulic breaker should be adjusted to balance it.


The reason for the oil leakage of the breaker

How to store the breaker in winter