Banner

行业知识

Home>Industry knowledge>Content

Protection and Application of Breaking Hammer Break-in Time

2021-06-29

  HammerThe use skills and maintenance of the running-in time are very important. After leaving the factory, it usually requires about 6 or ten hours of running-in time (some are called the running-in period), which is required by the manufacturer according to the technical characteristics of the initial application. The running-in time is a key step to ensure normal operation, reduce equipment failure rates, and increase its service life. Let's take a look at the maintenance and application of running-in time.

1. Pay attention to the running load during the running-in time. The running load during the running-in time usually cannot exceed 80% of the rated running load, and an appropriate amount of labor should be arranged to avoid the over-temperature problem caused by the long-term continuous operation of the equipment.

2. Pay attention to the indications of each instrument from time to time. If there is an abnormality, it should be stopped in time to eliminate it. Before the cause is not found and the common fault is not eliminated, the work should be stopped.

3. Because the breaker is a special vehicle, the actual operator should receive the manufacturer's learning and training, specific guidance, have sufficient understanding of the structure and characteristics of the equipment, and obtain the corresponding practical operation and protection experience before actually operating the equipment. The manufacturer provides The product application protection manual is the information required by the operator to actually operate the equipment. Before actually operating the equipment, be sure to read the application protection manual, and carry out the actual operation and maintenance according to the requirements of the manual.

Because of the lack of understanding of its structure and characteristics (especially for new operators), it is very easy to cause common failures and even equipment safety accidents due to work mistakes. Therefore, friends who use the application must carefully read the relevant operating instructions to avoid middle and late stages. At work, the breaker and excavator were destroyed, and the application rate was increased.


Common problems with the use of excavator breakers

Operation error performance of straight breaker